GBK51948 RHINO2
Installation Manual Issue 5
6.5.7.7 BatGauge Sensitivity
Parameter Possible Values Default HHP Lite Std Adv
BatGauge Sensitivity 0 170 40
Adjusts the speed with which the battery gauge reacts to voltage fluctuations of the
battery.
Batteries with a higher capacity take more time to discharge. For this reason, the battery
gauge should react slower with high-capacity batteries to ignore fast voltage fluctuations
that happen when the scooter encounters temporary loads such as a ramp.
If the battery voltage is less than the battery gauge currently indicates, the battery gauge
decreases by 5% after BatGauge Sensitivity x 1.5 seconds. The 100% range of the battery
gauge falls between Battery Gauge Minimum and Battery Gauge Maximum .
For better battery gauge accuracy, increase the value of BatGauge Sensitivity with high-
capacity batteries and decrease the value with low-capacity batteries.