28 CA 252/302/402 M252EN6
EVERY 1000 HOURS OF OPERATION (Every six months)
Rear axle planetary gears
– Oil change
Fig. 47 Planetary gear/drainage position
1. Plug
1
1
Fig. 48 Planetary gear/filling position
1. Plug
1
1
Std.
Optional
Std.
Optional
Position the roller with the plug (1) at its lowest position.
Wipe clean, unscrew the plug (1) and drain the oil into a
suitable receptacle. The volume is about 2 litres (2.1 qts).
Save the oil and deposit it in an approved
manner.
Position the roller with the plug at 9 o’clock.
Fill with oil to lower edge of level hole.
Refit the plug and repeat the process on the other side.
Use transmission oil. See the lubrication specification.