Maintenance - Every 2,000 hours
102 4812325557EN 2018-02-19
Lubricate the upper/lower pivot bearing
1. Lubricate the grease fitting of the upper pivot bearing (1)
and the grease fitting of the lower pivot bearing (2)
operating the grease gun manually with five pump strokes.
2. Use the grease according to the lubricant specifications
recommended by DYNAPAC.
1
2
Fig. - Pivot bearings
1. Upper pivot bearing grease fitting
2. Lower pivot bearing grease fitting