Fitting notes
Service manual
08
08 Remove the cover.
09 Important: ensure the entire
length of the cable is wound onto
the cable rewind assembly.
Prise the cable protector off the
side of the chassis.
10 Important: press the cable
rewind actuator and allow the
cable rewind assembly to turn
through two revolutions clockwise
to remove any remaining tension
in the cable spring assembly.
Failure to do this could result in
injury when removing the spring
assembly.
x2