Analog
input
1. Input voltage range: DC 0V10V
2. Impedance: 22kΩ
1. Input range: DC 0V10V/4mA–20mAdecided by selection
of P5-00.
2. Impedance: 22kΩ(voltage input),500Ω(current input)
AI1-GND
AI2-GND
AI3-GND
Analog input 
termianl 1
Analog input
termianl 2
Analog input
termianl 3
Digital
input
1. Optocoupler coupling isolation, compatible with dual
polarity input
2. Impedance: 2.4kΩ
3. Voltage range for level input: 9V-30V
4. S8 can be used for high-speed pulse input.
Maximum input frequency: 100kHz
S1-COM
Digital input 1
S3-COM
S2-COM
S4-COM
S5-COM
S6-COM
S7-COM
Digital input 3
Digital input 2
Digital input 4
Digital input 5
Digital input 6
Digital input 7
S8-COM
Digital input 8
Digital
output
Terminal
Commun-
ication
Function Description
Voltage or current output is decided by P5-32.
Output voltage range: 0V10V
Output current range: 0mA20mA
Contact driving capacity:
250Vac, 3A, COSØ=0.4.
30Vdc, 1A
AO1-GND
Y3-YC
Y4-YC
Y1A/Y1B/
Y1C
DA,DB
Y2A/Y2C
Name
Analog output
terminal 1
Relay digital
output 1
RS485 interface
Relay digital
output 2
Digital output
termianl 1
Digitaloutput
termianl 2
Type
Analog
output
1.Optocoupler coupling isolation, dual polarity open
collector output:
2.Output voltage range: 024 V
3.Output current range: 050 mA
4.Y4 is limited by F5-32 “HY function enable”. As high-
speed pulse output, the maximum frequency is 50 kHz.
5.Select whether YC terminal and COM terminal are
electrically connected through SW1.
1. Standard RS485 communication interface;
2. Select whether to connect 120O termination resistor
through SW2.
AO2-GND