Fu nct ion C ode T abl e
EC 600 0
Fu nct ion C ode T abl e
EC 600 0
0C09H
0C0AH
0C0BH
0C0CH
0
2.0s
0
3.00S
PC-09
PC-10
PC-11
PC-12
0: Fault
1: Continue to operate within the allowable
time of undervoltage recovery
2: Continue to operate after the power supply
returns to normal
0.1 60.0s
0: Invalid 1: Valid
0.0 120.00s
Solution of
undervoltage
fault
Allowable time
of undervoltage
recovery
Restart method
after power
failure
Waiting time
for restart
after power
failure
PD I n te rna l con tr ol PL C Fun ct ion a nd fr equ en cy pa ram et ers
Address
0D00H
Default
20.0%
Function
Code
PD-00
Setting Range
Parameter Name
Multi-
frequency 1
0D01H
40.0%
PD-01
Multi-
frequency 2
0D02H
60.0%
PD-02
Multi-
frequency 3
0D03H
80.0%
PD-03
Multi-
frequency 4
0D04H
100.0%
PD-04
Multi-
frequency 5
0D05H
80.0%
PD-05
Multi-
frequency 6
0D06H
60.0%
PD-06
Multi-
frequency 7
0~100.0%
0D07H
40.0%
PD-07
Multi-
frequency 8
0D08H
20.0%
PD-08
Multi-
frequency 9
0D09H
40.0%
PD-09
Multi-
frequency 10
0D0AH
60.0%
PD-10
Multi-
frequency 11
0D0BH
80.0%
PD-11
Multi-
frequency 12
0D0CH100.0%
PD-12
Multi-
frequency 13
0D0DH
80.0%
PD-13
Multi-
frequency 14
0D0EH
60.0%
PD-14
Multi-
frequency 15
0D10H
10.0
PD-16
Running time of
PLC reference 1
0D0FH0000
PD-15
PLC
running mode
BIT0: Circulation mode
0: Stop after the AC drive runs one cycle
1: Repeat after the AC drive runs one cycle
2: Keep final values after the AC drive runs one
cycle
BIT1:Chronograph unit
0: Second 1: Minute 2: Hour
BIT2: Power down storage mode
0: No 1: Yes
BIT3: Start-up mode
0: Rerun from stage one
1: Rerun from downtime
2: Continue operation with the rest of the
downtime phase
0.0~6500.0(s/m/h)
0D11H
10.0
PD-17
Running time of
PLC reference 2
0D12H
10.0
PD-18
Running time of
PLC reference 3
0D13H
10.0
PD-19
Running time of
PLC reference 4
0D14H
10.0
PD-20
Running time of
PLC reference 5
0D15H
10.0
PD-21
Running time of
PLC reference 6
0D16H
10.0
PD-22
Running time of
PLC reference 7
0D17H
10.0
PD-23
Running time of
PLC reference 8
0D18H
10.0
PD-24
Running time of
PLC reference 9
0D19H
10.0
PD-25
Running time of
PLC reference 10
0D1AH
10.0
PD-26
Running time of
PLC reference 11
0.0~6500.0(s/m/h)
0D1BH
10.0
PD-27
Running time of
PLC reference 12
0D1CH
10.0
PD-28
Running time of
PLC reference 13
0D1DH
10.0PD-29
Running time of
PLC reference 14
0D1EH
10.0PD-30
Running time of
PLC reference 15