Installation, Operation and Parts Manual
EE-6503V2
TROUBLE SHOOTING
ATTENTION: If the trouble could not be fixed by yourself, please do not hesitate to contact us for help. We will offer our service at the
earliest time we can. The troubles will be judged and solved much faster if you could provide us more details or pictures of the trouble.
Motor does not run and
will not raise.
Check and make a good connection.
Damaged limit switch or its wire connection is loose.
Adjust or replace the limit switch.
Motor runs but will not
raise.
Check the wire connection.
Overflow valve is not well screwed up or jammed.
The hose connection is loose.
The cushion valve is not well screwed up or jammed.
Platforms go down
slowly after being
raised.
Untightened oil cylinder.
The single way valve leaks.
Solenoid valve fails to work well.
Check and adjust the tightness.
The overflow valve is not adjusted to the right position.
Too hot hydraulic oil ( above 45°).
Abraded seal of the cylinder