Switch 4: Reverse Loop - Sets the reverse
loop to be normally open or to normally
close. It is useful in Fail-Safe applications.
Switch 5: One Pass (On/Off) - This tailgating
feature works with the reverse loop to allow
only one car to pass. After the car passes,
the gate closes instantly. If a second car
approaches the gate stops. The operator
resumes closing after the car leaves.
Switch 6: Stop-Reverse (On/Off) - This radio
feature allows the transmitter to work as a
three-button station and is useful for a partial
opening. If selected, the first command will
open the gate, the second will stop the gate,
and the third will close the gate.
Switch 7: Alarm Reset (On/Off) - If the "on"
position is selected, after the five minutes
"shut down" time period the operator will
reset and any input will be accepted. Norm-
ally, the power must be turned off to reset.
Switch 8: Close Timer (On/Off) - Sets the
Close Timer to the "on" or "off" position.