Do you have a question about the Eaton 5PX Gen2 and is the answer not in the manual?
Model | 5PX Gen2 |
---|---|
Category | UPS |
Manufacturer | Eaton |
Topology | Line-interactive |
Output Frequency (battery mode) | 50/60 Hz ± 0.1 Hz |
Audible Alarm | Yes |
Operating Temperature | 0 to 40 °C |
Storage Temperature | -15 to 45 °C |
Relative Humidity | 0-95% non-condensing |
Power Rating | 1000 VA - 3000 VA |
Output Power Capacity | 1200-2700 W (model dependent) |
Input Voltage | 230 V |
Output Frequency | 50/60 Hz |
Input Frequency Range | 45-65 Hz |
Transfer Time | 2-6 ms |
Battery Type | Sealed lead-acid battery |
Battery Runtime | Varies by load |
Typical Recharge Time | 3 hours to 90% capacity |
Communication Ports | USB, Serial |
Management Interface | LCD display |
Display | LCD |
Agency Approvals | CE, UL, cUL, FCC |
Form Factor | Tower |
Details Eaton's environmental-protection policy and eco-design approach for products.
Highlights advantages like ABM technology, extended runtime, and communication options.
Describes tower and rack installation procedures for the UPS units.
Illustrates and labels all ports and connectors on the rear of the UPS.
Lists and describes optional accessories compatible with the Eaton 5PX UPS.
Provides instructions for checking the UPS for shipping damage and filing claims.
Details proper placement and spacing for tower UPS installation for optimal ventilation.
Explains how to connect Extended Battery Modules (EBMs) to the UPS.
Guides connecting the UPS to AC power and loads, including priority connections.
Details connecting the FlexPDU optional module to the UPS for power distribution.
Explains the connection process for the HotSwap Maintenance Bypass Module.
Describes the front panel controls, indicators, and screen for monitoring UPS status.
Explains the information shown on the UPS LCD screen, including status and measurements.
Details the menu structure and functions for UPS configuration and monitoring.
Covers user-adjustable settings like language, LCD, audible alarm, and output voltage.
Instructs connecting RS232 and USB ports for UPS management software.
Explains using connectivity cards and inputs for remote UPS control and monitoring.
Guides initial startup, configuration, and normal operating conditions of the UPS.
Details starting the UPS when disconnected from AC power.
Provides instructions for safely shutting down the UPS unit.
Explains normal, battery, and low-battery states of the UPS.
Covers automatic battery tests, low battery warnings, and external battery setup.
Explains how to access and view UPS event and fault logs for diagnostics.
Provides guidelines for cleaning, temperature control, and storing the UPS.
Details when to replace batteries and essential safety precautions.
Step-by-step instructions for safely replacing the UPS internal batteries.
Describes replacing the UPS unit while using a HotSwap Maintenance Bypass Module.
Advises on contacting local centers for proper disposal and recycling of used UPS equipment.
Guides on checking logs to diagnose typical UPS alarms and operational issues.
Explains alarm silencing and provides contact for service/support.
Lists Eaton 5PX UPS models, catalog numbers, power ratings, and configurations.
Details EBM catalog numbers, configurations, voltage, and compatibility.
Provides physical specifications, including weight and dimensions for UPS and EBM units.
Details input frequency, nominal frequency range, and voltage window.
Specifies input connection types and cables for different UPS models.
Describes output voltage regulation, efficiency, frequency, and overload handling.
Details output connection types and cables for UPS primary and group outlets.
Covers internal and external battery specs, monitoring, and cable lengths.
Lists safety standards, EMC compliance, agency markings, and operating environment parameters.