EATON HFX Product Family Installation and Operation Manual E-ELCL-II002-E2 July 2019 25
HFX Product Family
The system conguration has a second tab, the
system cong conguration that enables the user
to congure settings for Regulator Voltage, CAN 1
Termination, Watchdog Time, and Low Memory
Fault threshold.
Note: That depending on the parameter, double clicking
the value in the appropriate value eld will either open
a drop down menu to select, allow direct editing or toggle
the variable (see picture below).
15.2 Input Modes
The controller has either 6, 10, 16 or 24 inputs
available for use, depending on the selected model.
The specic inputs are as follows:
• Congurable Analog/Digital Inputs
• Congurable Frequency/Digital Inputs
• Congurable Differential Frequency/Digital Inputs
These different congurations are possible through
selection of the appropriate mode in the PLC
conguration tab in the IDE (see screens below).
15.3 Analog Conguration
Figure 1: Analog/Digital Inputs I/O Mapping tab.
This is the area where analog or digit input values
are mapped to addresses. These variables are all
accessible in the application program.
Variables:
• AnalogInValue#: Analog value with units
dependent upon congured mode.
• AnalogInBinaryValue#: Digital value after debounce
and rising/falling voltage thresholds are applied.
Note: # above represents input numerical
16, 10, 6, or 4 of the inputs (depending on the model
chosen) can be congured as either Analog or Digital.
Both the Analog and Digital value have a name,
value, address, type and description associated.
The name can be altered by the programmer,
if desired. Analog Inputs are displayed in actual
engineering units depending on the mode
conguration (either Voltage – mV, Current – μA,
Resistance - Ω, or Temperature °C). Binary inputs are
evaluated as true or false and our bits.