MN04002001E
 
15
 
March 2006
 
Step 4 — Parameter Groups & Default Values (Continued)
80 — KEYPAD/DISPLAY (Continued)
90 — COMMUNICATION PARAMETERS
Modbus Groups Description Range Default
User
Settings
0606H 80.07 Keypad Display 
selection
(also order of 
appearance when 
scrolling through 
display modes)
00: Command Frequency ("F") 00
01: Output Frequency ("H")
02: Output Current ("A")
03: User Defined ("U")
04: Output Voltage (u)
05: Unit Temperature (t)
06: Forward/Reverse Direction ("Frd 
/ rEv") 
display only when enabled: Counter 
("c")
xx
display only when enabled: PLC 
steps
display only when enabled: PID 
Feedback
0607H 80.08 User Defined 
Multiplier
0.01 to 160.00 1.00
0608H 80.09 External Terminal 
Scan Time
01 to 20 01
0609H 80.10 Parameter Lock and 
Configuration
00: All parameters can be set and 
read
00
01: All parameters are read only
10: Reset all parameters to the 
factory defaults
060AH 80.11 Elapsed Time (Run): 
Day
0 to 65535 (show 6553.) 0
060BH 80.12 Elapsed Time (Run): 
Minutes
0 to 65535 (show 6553.) 0
060CH 80.13 Elapsed Time (Power 
on): Day
0 to 65535 (show 6553.) 0
060DH 80.14 Elapsed Time (Power 
on): Minutes
0 to 65535 (show 6553.) 0
060EH 80.15 Automatic Display 
Scroll
00: Disable
01: Scroll every 5 seconds after 1 
minute delay
02: Scroll every 15 seconds after 1 
minute delay
00
Modbus Groups Description Range Default
User
Settings
0700H 90.01 Communication 
Protocol
00: MODBUS ASCII mode 
< 7 data bits, no parity, 2 stop bits >
00
01: MODBUS ASCII mode 
< 7 data bits, even parity,
1 stop bit >
02: MODBUS ASCII mode 
< 7 data bits, odd parity, 
1 stop bit >
03: MODBUS RTU mode 
< 8 data bits, no parity, 2 stop bits >
04: MODBUS RTU mode 
< 8 data bits, even parity,
1 stop bit >
05: MODBUS RTU mode 
< 8 data bits, odd parity,
1 stop bit >
0701H 90.02 RS-485 
Communication
01 to d 254 01
0702H 90.03 Transmission Speed  00: 4800 baud 01
01: 9600 baud
02: 19200 baud
03: 38400 baud
 
MN04002001E.fm  Page 15  Thursday, April 13, 2006  11:11 AM