7
Instruction Leaet PUB53675
Effective December 2021
PowerXL DM1 and DM1 Pro series VFD 
 
 
EATON www.eaton.com
FR1 mounting instructions
Step 1. 
Lift the drive out from the carton and remove the packaging.  The 
magnetic cores and cable ties are only included in EMI version drive.
Step 2. 
Screw mounting: Attach the drive to the mounting plate with 
two M5x20 (or 3/16 in.) screws and two M5 (or 3/16 in.) nuts.  The 
opening dimension on the mounting plate should follow required 
dimension (refer to the dimension drawing in Table 1 of this docu-
ment).
DIN Rail mounting: Lift the drive at an angle about 30 degrees.  
Align the top hooks of drive DIN rail mounting slot with DIN rail top 
edge.  Push down and rotate the drive to clip the bottom hooks on 
the bottom DIN rail edge.
Step 3. (EMI version only):
The input wires (including 3 line wires and 1 input grounding wire) 
should run through the input magnetic core before connecting to 
input terminal block and grounding hole.  Use a cable tie to tie the 
input magnetic cores to the input wires.  The output wires (only 3 
motor wires) should run through the output magnetic core before 
connecting to output terminal block.
The output grounding wire should not run through the output 
magnetic core.  Use a cable tie to tie the output magnetic cores to 
the output wires.  The maximum distance between input / output 
magnetic cores top surface and drive bottom surface is 100 mm 
(3.94 in.).  The input magnetic core and output magnetic core are the 
same for FR1.
+
Screw mounting
Two M5x20 or 3/16 inch screws
Two M5 or 3/16 inch nuts
Torque: 3 N.m (26.6 lb/in.)
DIN Rail mounting
Input grounding wire
Output grounding wire
Max. distance: 100 mm (3.94 in.)
3 motor wires
Input magnetic core
Output magnetic core