16
Inquiry
AT+ADV?
+OK=[para]
Set
AT+ADV=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para
(
ASCII
)
Description
0
Turn off
1
Turn on
(
default
)
2
iBeacon
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off;
2. The slave or master-slave integrated supports broadcasting.
6.4.12 AT+ADVDAT advertising data
Command
Response
Inquiry
AT+ADVDAT?
+OK=[para]
Set
AT+ADVDAT=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(HEX):
1
、
Support ASCII
、
HEX
2
、
Length is less than 26 bytes.
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time).
Save when power off;
2. The slave or master-slave integration supports broadcasting, and other roles can still be configured;
For example,
Command:41 54 2b 41 44 56 44 41 54 3d 31 32 33 34 35 36 37 38 39 30;
Adv data:31 32 33 34 35 36 37 38 39 30
6.4.13 AT+ADVINTV advertising interval
Command
Response
Inquiry
AT+ADVINTV?
+OK=[para]
Set
AT+ADVINTV=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ASCII):20~10240
default
:
1000
(
1S
)
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off
2. The slave or master-slave integrated supports broadcasting, other roles can still be configured;
For example,
AT+ADVINTV=1000