EasyManua.ls Logo

Ebyte E104-BT52 - 6.4.37 AT+SLEEP enter sleep; 6.4.38 AT+LOGMSG operating status output; 6.4.39 AT+PWR TX power

Ebyte E104-BT52
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co.,Ltd
24
Set
AT+ONSLEEP =[para]
+OK
success
+ERR=[NUM]
error
Parameter
paraASCII
Description
0
Off(default)
1
On
Note
Take effect immediately, save when power off
6.4.37 AT+SLEEP enter sleep
Command
Response
Set
AT+SLEEP
+OK
Parameter
None
Note
Take effect immediately
6.4.38 AT+LOGMSG operating status output
6.4.39 AT+PWR TX power
Command
Response
Inquiry
AT+ PWR?
+OK=[para]
Set
AT+ PWR =[para]
+OK
success
+ERR=[NUM]
error
Parameter
para(ASCII)
Description
0
2.5 dBm
1
1.5 dBm
2
0 dBm
default
Command
Response
Inquiry
AT+LOGMSG?
+OK=[para]
Set
AT+LOGMSG =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para
ASCII
Description
0
Off(default)
1
On
Note
Take effect immediately, save when power off

Table of Contents