6.4.14 AT+IBCNVER iBeacon broadcasting version command
Command
Response
Inquiry
AT+IBCNVER?
+OK=[para]
Set
AT+IBCNVER=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
paraASCII
Description
0
Old version iBeacon broadcasting
1
New version iBeacon broadcasting
default
Note
1.Take effect immediately , save when power off
2.For new version iBeacon broadcasting, iBeacon Prefix contains 9 bytes; while old version only contains 6
bytes
3.Software version 7212-1-12 supports this command
For example,
AT+ADVINTV=1
6.4.15 AT+IBCNUUID iBeacon UUID command
Command
Response
Inquiry
AT+IBCNUUID?
+OK=[para1]
Set
AT+IBCNUUID=[para]
+OK
success
+ERR=[NUM]
error
Parameter
para(HEX)16 bit UUID
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off
2. The slave or master-slave integrated supports broadcasting, other roles can still be configured;
For example,
Set iBeacon UUID as “FDA50693A4E24FB1AFCFC6EB07647825”
41 54 2B 49 42 43 4E 55 55 49 44 3DFDA50693A4E24FB1AFCFC6EB07647825
6.4.16 AT+MAJOR iBeacon Major command
Command
Response
Inquiry
AT+MAJOR?
+OK=[para]
Set
AT+MAJOR=[para]
+OK
success
+ERR=[NUM]
error
Parameter
para(HEX)
0X0001-0XFFFF
default
Note
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
save when power off;
2. Only the slave device supports broadcasting, other roles can still be configured;

Table of Contents

Related product manuals