Ebyte E104-BT52 - 6.4.24 AT+BONDMAC add bound MAC address; 6.4.25 AT+BONDDEL delete bond MAC address; 6.4.26 AT+SCAN scan

Ebyte E104-BT52
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co.,Ltd
20
+ERR=[NUM]: error
Parameter
Para0(ASCII)
Description
Para1ASCII: connected device role + connected
device MAC address + send data to the handle of the
connected device
0~1
Connection number
Note
Effective immediately. Sending data to the handle of the connected device is only valid when our device is
the master.
For example,
CommandAT+CONNIFO=0
6.4.24 AT+BONDMAC add bound MAC address
Command
Response
Inquiry
AT+BONDMAC?
+OK=[sum][ [mac] [mac]…]
Set
AT+BONDMAC=[mac]
+OK
success
+ERR=[NUM]
error
Parameter
sum(HEX): sum of currently bound MAC address
mac(HEX)
6bytes mac address;
Note
1. Take effect immediately, save when power off
2. When no MAC address is bound, no data will be returned
For example,
InquiryAT+BONDMAC?
Return: 2B 4F 4B 3D 03 CC 34 27 1A 0C D4 3D AC 82 16 0F 58 D2 D4 C3 07 0E C4
Set41 54 2B 42 4F 4E 44 4D 41 43 3D CC 34 27 1A 0C D4
Return+OK
6.4.25 AT+BONDDEL delete bond MAC address
Command
Response
Set
AT+BONDDEL=[mac]
+OK
+ERR=[NUM]
Parameter
mac
6 bytes mac address
Note
1
Take effect immediately, save when power off
2
Delete specific mac address
6.4.26 AT+SCAN scan
Command
Response
Inquiry
AT+SCAN?
+OK=[para]
Set
AT+SCAN=[para]
+OKsuccess
+ERR=[NUM]error