21
opEratIon
WARNING
• Never smoke or use broken connectors on the battery while charging.
Sparks may ignite the battery gas.
• Battery electrolyte is poisonous and dangerous, causing severe
burns, etc. contains sulfuric (sulphuric) acid. Avoid contact with skin,
eyes or clothing.
• Antidote:
EXTERNAL: Flush with water.
INTERNAL: Drink large quantities of water or milk. Follow with milk
of magnesia, beaten egg or vegetable oil . Call physician immediately.
EYES: Flush with water for 15 minutes and get prompt
medical attention.
• Batteries produce explosive gases. Keep sparks, flame, cigarettes,
etc., away. Ventilate when charging or using in closed space.
Always wear eye protection when working near batteries.
• Keep out of reach of children.
AC PARALLEL OPERATION
Before connection an appliance to either generator, make sure that it is in
good working order and that its electrical rating does not exceed that of
the receptacle.
During parallel operation, the ESC switch should be in the same position
on both generators.
1. Connect the parallel operation cable between the generator to either
the main generator or companion generator following the instructions
supplied with the cable kit.
2. Start the engines and make sure the output indicator (green) on each
generator comes on.
3. Plug an appliance into the AC receptacle.
4. Turn on the appliance.