opEratIon
Application range
When using the generator, make sure the total load is within rated output
of a generator. Otherwise, generator damage may occur.
AC
Power
Factor
1 0.8-0.95 0.4-0.75
(Efficiency
0.85)
Rated
output
power
1,600W 1,280W 544W Rated
voltage 12V
TIP:
• Application wattage indicates when each device is used by itself.
• The simultaneous usage of AC and DC power is possible but total
wattage should not exceed the rated output.
EX:
The overload indicator (1) comes on when total wattage exceeds the
application range. (See page 11 for more details.)
Generator rated output 1,600W
Frequency Power factor
AC
1.0 1,600W
0.8 1,280W
DC --- 100W (12V/8.3A)