149/157
SDi Decades Extreme Service Manual www.ecoer.com
May. 2023Manufacturer reserves the right to change specifications or designs without notice.
WARNING: Evacuate the system and confirm that there is no refrigerant left in the system before removing the
four-way valve and the compressor. (For R32 & R290, you should evacuate the system with the vacuum pump;
flush the system with nitrogen; then repeat the two steps before heating up the brazed parts. The operations
above should be implemented by professionals.)
Note: Remove the panel plate, connection of compressor on PCB (refer to 10.2.1 Panel plate and 10.2.2
Electrical parts) before disassembling sound blanket.
1) Remove the flange nut of terminal
cover and remove the terminal cover
(see ODU_COMP_1).
2) Disconnect the connectors (see ODU_
COMP_2).
Note: This section is for reference only. Actual unit appearance may vary.
10.2.7 Compressor
Terminal Cover