79/157
SDi Decades Extreme Service Manual www.ecoer.com
May. 2023Manufacturer reserves the right to change specifications or designs without notice.
Low ambient temperature protection
Mismatch between the new and old platforms
For other errors:
The display board may show a garbled code or a code undefined by the service manual. Ensure that this
code is not a temperature reading.
Troubleshooting:
Test the unit using the remote control. If the unit does not respond to the remote, the indoor PCB requires
replacement. If the unit responds, the display board requires replacement.
LED flash frequency:
... ...
8.2.2 Error Display on Two Way Communication Wired Controller
Malfunction or Protection
Communication error between wire controller and indoor unit
The other error codes displayed on the wire controller are same from those on the unit.