7
www.eacoon.com
EN
420010511800
TECHNICAL DATA
GAS CATEGORY BY COUNTRY
MODEL BLU 7000.1 BLU 8000.1 BLU 10000.1 BLU 12000.1
Thermal power max.
kW
7.500 8.500 10.500 13.000
kcal/h
6.450.000 7.310.000 9.030.000 11.180.000
Thermal power min.
kW
1.500 2.000 2.500 2.700
kcal/h
1.290.000 1.720.000 2.150.000 2.322.000
Operation mode
Type
Progressive mechanical gas - Modulating with PID
Regulation ratio nominal
Type
1÷4 GAS
Fuel
Type
G20 (L.C.V. 8.570 kcal/Nm
3
), G25 (L.C.V. 7.370 kcal/Nm
3
)
G31 (L.C.V. 22.260 kcal/Nm
3
), G30 (L.C.V. 29.320 kcal/Nm
3
)
Emission class
std
Standard Class 2 - GAS EN676 (<120 mg/kWh)
Control unit
Type
LFL / LGK
Gas train
GT
VGD separate gas train + Filter + KIT Tightness control + Other KIT/ACS
Gas connection
GTCP
Gas connection range DN65 to DN125 depending on the gas train selected
NATURAL GAS pressure
mbar
60÷700 85÷700 115÷700 175÷700
LPG pressure
mbar
125÷700 185÷700 110÷700 160÷700
Air regulation
Type
Air flap Air flap Air flap Air flap
Air flap control with servomotor
Model
SQM50
Air pressure switch
mbar
1…10 mbar
Flame monitoring
Type
Ionization
Ignitier
Model
COFI
Motor
kW
15 18,5 22 37
Rpm
N°
2.800 2.800 2.800 2.800
Voltage
V/Hz
230/400 V - 50 Hz
Tot. power consumption operation
W
16.500 20.000 23.500 38.500
Weight body BBCH
Kg
Electrical panel protection level
IP
IP40 IP40 IP40 IP40
Sound pressure level
without silencer
dB(A)
Lab tests
94,1 94,6 95,6 96,3
Sound pressure level
with silencer
86,9 87,8 88,1 88,9
Ambient temperature storage
Min/Max
-20°…+70° C
Ambient temperature use -10°…+60° C
Gas category Country
2,3 Family
AT BE BG CH CY CZ DE DK EE ES FI FR GB GR HU IE IS IT LT LU LV MT NL NO PL
PT RO SE SI SK AL HR MK TR - - - - - - - - - - - - - - - -