Installation preparations:
Fig. 5: Removal of the electronic unit
1. Hold down the release tab of the funnel lock.
2. Push the funnel lock (pos. 1) upwards and remove it.
ð
The funnel is now unlocked.
3. Remove the funnel (pos. 2) upwards.
4. Press both buttons (pos. 3) of the housing (right and left).
ð
The housing is unlocked.
5. Remove the housing (pos. 4) by pulling it forward.
ð
The electronics housing is exposed.
6. Press both tabs (pos. 5) of the electronics housing (right and left).
ð
The electronics housing is unlocked and can be removed completely
.
ð
The buzzer volume (alarm) can be set here (pos. 6).
7. Press all four tabs (pos. 7) of the electronics housing cover (right and left).
ð
The electronics housing cover is unlocked and can be removed.
8. The PCB is now exposed and the electrical installation can begin.
Assembly and installation
19 417102610 Rev. 01-12.2020