417101634_Lubo-DryExx_Advanced
- 54 -
Rev. 07-01.15
11. Fault Checking
WARNING
The remedying of defects in circuits that are live, or under pressure, should only be
carried out by specialist qualified personnel.
Error indication
Cause / Fault
Remedy
No suction at applicator
pump
See pump handbook See pump handbook
Reduced applicator
performance
Air control circuit produces to
little pressure
Check filter pressure regulator and
3/2 way solenoid valve
Check compressed air circuits
No pressure build up in
the lubrication circuits
Check circuit pipes
Eliminate leakages
Raise operating air pressure
Check pressure release
valve
Clean or replace valve