EasyManua.ls Logo

EcoWater ESM15CE - Page 9

EcoWater ESM15CE
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
ECOWATER
SYST E MS
Planning Installation
Other Requirements
A 220V--50Hz, grounded electrical outlet (continuously ‘live’’) is needed within 2 meters of the unit.
A drain is needed for regeneration discharge water. A floor drain, close to the unit, is preferred. A laundry tub,
standpipe, etc., are other drain options.
STANDPIPE
4cm
Airgap
Drain
Hose
4cm
Airgap
Drain
Hose
LAUNDRY TUB
Figure 3
Tools and Materials You May Need
Common Screwdriver Tape Measure
Pliers Pipe and fittings as required
Soldered Copper
Tubing cutter LEAD --FREE solder and flux
Propane torch Emery cloth, sandpaper or steel wool
Misc. fittings
Threaded
Pipe cutter or hacksaw Pipe joint compound
Threading tool Misc. fittings
CPVC Plastic
Pipe cutter Solvent cement
Hacksaw Primer
Adjustable wrench Misc. fittings
NOTE: The salt storage tank drain elbow accepts either 1/2” or 3/8” I. D. hose.
VALVE DRAIN OPTIONS: Flexible drain hose is not allowed in all localities (check your plumbing codes). For a
rigid valve drain run, cut the barbed section off the drain fitting for access to the 1/4” pipe threads. Then plumb
a rigid drain as needed (see Figure 4).

Related product manuals