5. ADJUSTMENT AND SETTING V-65E-A
5-6
5.8 Maintain notice-key switch
5.8.1 If the safety cover is open, the bar feeder can’t use the automatic mode, but it still
can be use manual mode.
(1) Need to use the automatic mode when the safety cover is open. Please turn
the key-switch to “OFF”. The bar feeder can be use the automatic
mode.
(2) If the bar feeder alarm and you have eliminated the breakdown. And then need
to use the automatic mode, please close the power.
Turn the key-switch to “ON” , and close the safety cover. Then open
the power and it can be operation on automatic mode.
! IMPORTANT! The key-switch has to turn to “ON” , --otherwise the program
can’t to determine alarm to be directed against the safety cover.
5.8.2 Check the safety-switch location
When LCD display ”cover not close”, please check 3 safety-switches (show as in Fig)
whether they go back to the location. Then press “F3” at the same time and the bar
feeder can be working in normal.
(Note)
1. In normal running, please don’t
open the safety cover lest to
cause alarm.
2. Please don’t pull out the
connect plug from the remote
control box lest to cause alarm.