Draining the Unit
When the portable air conditioner is in cooling mode, or dehumidify mode, it will remove moisture
from the air. The condensed water from the air will be collected in an internal reservoir and will be
evaporated and exhausted out of the exhaust hose. However, in very humid conditions, the
internal reservoir may fill completely. This causes the air conditioner to turn off to avoid
overflowing the internal reservoir. The WATER indicator will light up on the Control Panel.
Direct Drainage
1. Remove the rubber drain plug from the drain port.
2. Connect a drain hose to the drain port.
The portable air conditioner will now drain through the drain hose. Please note that this unit has no
drain pump; all water will drain with gravity only, i.e., only “downhill.”
Drainage Options
This portable air conditioner comes with several different options to drain water accumulated
during operation. The most common will be the self-evaporative mode. The unit will do this
automatically. This mode will be sufficient for most environments. If you are operating the unit in
an environment with higher levels of humidity you may choose the continuous drainage option to
help remove the excess water.
Continuous Drain
This unit has the capacity for continuous drainage. It includes an
internal
pump to help
remove water. The benefit is the unit will push
the
water to the drain instead of relying on
gravity for the water to
reach
the drain. If there is an obstacle in between the unit and the
drain
the pump will push the water over that obstacle through the water line. There is also
the option to run the water line through
the
window panel with the hole in between the two
grated adapters.
In
any method you must ensure the water line is run to a proper
drain
or
area that can accept and remove water. In order to
run the
continuous drain you will need to
do the
following:
1. Connect the included water line to the unit. You will need to attach the quick connect
adapter on the end of the water line to the back of the unit.
2. Place the other end of the water line (drainage end) into a drain.
The unit will recognize that the quick adapter is attached and will automatically engage the
water pump. The pump will turn on once the water reservoir becomes full.

Other manuals for EdgeStar AP14009COM-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EdgeStar AP14009COM-1 and is the answer not in the manual?

EdgeStar AP14009COM-1 Specifications

General IconGeneral
BrandEdgeStar
ModelAP14009COM-1
CategoryAir Conditioner
LanguageEnglish

Related product manuals