Fault Descriptions
Low Battery
A low battery fault will register when the system detects a low capacity back-up battery.
The system automatically performs a battery test every 4 hours and also every time you arm
the system.
Date and Time
The date and time fault will register every time the system has been powered down. This
type of fault will not cause the FAULT indicator to display on the codepad unless your
installer has programmed the automatic arming time. Refer to page 17 to program the date
and time.
Sensor Watch Fault
A sensor watch fault will register because one or more detection devices has failed to detect
any movement during the disarmed state for the time period programmed by your installer.
The fault will clear once the zone in question has detected movement and reset.
Whilst you are in fault analysis mode, holding down button 5 until two beeps are heard will
display which zone reported the sensor watch fault.
Horn Speaker Fail
This fault will register when the system detects that the horn speaker has been disconnected.
This fault will clear once the horn speaker has been reconnected. Your installer will need to
program the system for this feature to operate.
Telephone Line Fail
A telephone line fault will register when the system detects that the telephone line has been
disconnected from the control panel. Your installer will need to program the system for this
feature to operate.
E2 Fault
An E2 fault will register when the system detects an internal checksum error. Contact your
installer as soon as this fault is displayed.
Fuse Fail
This fault will occur when either of the two 1 Amp fuses has blown. Contact your installer
as soon as this fault is displayed.
Communication Fail
A communication failure fault will register if the control panel was unsuccessful in calling
the receiving party after the control panel has exhausted its maximum number of attempts.
AC Mains Fail
An AC mains failure will flash the MAINS indicator, sound the codepad buzzer once every
minute and send an ‘AC Fail’ report to your security company. This fault will clear once the
system detects that the AC mains supply has been restored. The system will send an ‘AC
Restore’ report to your security company after the AC mains supply has restore continuously
for two minutes.