Technical data
M561-00-880 Issue C
2.2 Performance data
Table 3 - Performance data
Pump
Characteristics
Typical peak pumping speed
Ultimate
(shaft seal purge only)
Maximum continuous inlet pressure
Units m
3
/h mbar mbar
iXH100 100 < 3 x 10
-2
1000
iXH200H 215 < 3 x 10
-2
1000
iXH450H 500 < 3 x 10
-2
1000
*
*
Speed may be limited
iXH500H 500 < 3 x 10
-2
1000
*
iXH610 665 < 5 x 10
-3
1000
iXH1210/H 1025 - 1065 < 5 x 10
-3
1000
iXH1220H/T 1200 - 1250 < 5 x 10
-3
1000
iXH1820/H/T 1700 - 1900 < 5 x 10
-3
1000
iXH3030/T 2750 - 2900 < 5 x 10
-3
1000
*
iXH3045H 3225 < 5 x 10
-3
1000
*
iXH3050H 3200 < 5 x 10
-3
1000
*
iXH4545HT 4450 < 5 x 10
-3
1000
*
iXH4550HT 4220 < 5 x 10
-3
1000
*
iXH6045H/T 5000 - 5200 < 5 x 10
-3
1000
*
iXH6050H/T 5000 - 5200 < 5 x 10
-3
1000
*
pXH4500 N/A < 5 x 10
-3†
†
Ultimate achieved when pXH used in conjunction with an appropriate backing pump. Please contact Edwards to discuss your application. The pXH does not
have a shaft seal purge.
1000
*
pXH6000 N/A < 5 x 10
-3†
1000
*
iXL250Q 1900 < 1 x 10
-3
1000
*
iXL500Q 2150 < 5 x 10
-3
1000
*
iXL500R 3100 < 5 x 10
-3
1000
*
iXL750Q 2300 < 1 x 10
-3
1000
*
iXL750R 3450 < 1 x 10
-3
1000
*