Technical data
M561-00-880 Issue C
2.5 Electrical data
Table 7 - Electrical data iXH100 to iXH1820/H/T
Characteristics iXH100 iXH200H iXH450H iXH500H iXH610 iXH1210 iXH1210H iXH1220H/T iXH1820/H/T Units
Dry pump motor rating 4.5 7.5 11 11 4.5 4.5 7.5 7.5 7.5 kW
Mechanical booster
motor rating
----1.94.54.54.54.5kW
Current rating
(200 - 230 V systems)
21 38 44 44 28 28 38 38 38 A
Current rating
(380 - 460 V systems)
11 20 23 23 14 14 20 20 20 A
Recommended branch
circuit fuse UL
(200 - 230 V systems)
25 45 55 55 35 35 45 45 45 A
Recommended branch
circuit fuse IEC
(200 - 230 V systems)
25 40 45 45 30 30 40 40 40 A
Recommended branch
circuit fuse UL
(380 - 460 V systems)
15 25 30 30 20 20 25 25 25 A
Recommended branch
circuit fuse IEC
(380 - 460 V systems)
15 20 25 25 15 15 20 20 20 A
Min cable size for 200 -
230 V systems (or
corresponding AWG
size)
6 (8)
*
10 (6) 10 (6) 10 (6) 6 (8)
*
6 (8)
*
10 (6) 10 (6) 10 (6) mm
2
(AWG)
Min cable size for 380 -
460 V systems (or
corresponding AWG
size)
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)
*
*
The minimum geometric wire gauge for Han
®
K 4/4 is 6mm
2
and minimum AWG size is 8 AWG
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)
*
mm
2
(AWG)
Mains connector Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 Han
®
K 4/4 -