Table 35
Alarm acons
Alarm Descripon
Alarm stops
dry pump
Alarm stops
booster pump
Alarm overrides
Run 'l crash
EMS or system conguraon (set-up)
fault
Yes Yes Yes
Exhaust pressure Yes Yes Yes
Booster stator or end cover temperature No Yes No
Dry pump stator or end cover tempera-
ture
Yes Yes No
Booster status No Yes Yes
Dry pump status Yes Yes Yes
8.3 Unplanned shut down and alarms
The system has a number of pump protecon sensors that will give warnings and alarms,
refer to Table: Pump protecon sensors.
Table 36
Pump protecon sensors
Sensor
Warning condion trig-
g
ered (°C)
Alarm condion triggered
(°C)
Exhaust pressure transducer
▪ All variants
0.35 barg (5 psig) 0.55 barg (8 psig)
Dry pump stator temperature
▪ iXM200
120 130
▪ iXM200T
137 140
▪ iXM600
120 130
▪ iXM600T
137 140
▪ iXM1200
120 130
▪ iXM1200T
137 140
▪ iXM1200TX
137 140
▪ iXM3000
120 130
Dry pump motor temperature
▪ Standard and T variants
70 80
Dry pump end cover temperature
▪ T
*
and TX
105 110
Booster pump motor temperature
▪ iXM600
70 80
▪ iXM600T
70 80
▪ iXM1200
70 80
▪ iXM1200T
70 80
Booster pump stator temperature
▪ iXM1200TX
135 140