7.7.8
Lamp
check/replacement
Electric
Shock
Ensure
all
electrical
power
has
been
removed
and
the
main
circuit
breaker
has
been
turned
off
due
to
the
presence
of
high
voltage
or
current.
Caution
Should
a
lamp
require
replacement,
notify
the
appropriate
personnel
that
an
EMO
condition
will
occur.
Failure
to
follow
these
instructions
may
result
in
the
shut-down
of
the
process
tool
and
associated
equipment.
Visually
verify
that
the
POWER
ON
and
RESET
lamps
are
working.
If either
lamp
needs
replacement
and
the
proper
authorization
has
been
obtained:
1.
Press
STOP.
2.
Turn
off
the
main
circuit
breaker
(CB1).
3.
Disconnect
power
cord
from
mains
power
supply.
4.
Locate
the
two
securing
screws
on
the
front
electrical
panel
and
loosen
.
Open
the
electrical
drawer.
5.
If
replacing
the
POWER
ON
lamp,
locate
contactor
block
(LPl)
on
the
back
side
of
the
front
electrical
panel.
If
replacing
the
RESET
lamp,
locate
contactor
block
(PBl)
on
the
back
side
of
the
front
electrical
panel.
6.
Pry
up
the
metal
retaining
ring attached
to
the
coupling
plate.
Remove
the
contact
block
assembly.
7.
Replace
the
defective
lamp.
8.
Reinstall
the
contact
block
assembly
by
snapping
it
back
onto
the
front
clement.
9.
Close
the
electrical
drawer
and
tighten
securing
screws.
10.
Reconnect
mains
power
and
turn
on
the
main
circuit
breaker
(CBI)..
The
POWER
ON
lamp
should
be
illuminated.
11.
Press
RESET.
The
lamp
should
illuminate.
Press
START
to
reactivate
the
TCU.
Figure
11
-
Lamp
replacement
TCU40/80
Temperature
Control
Unit
29