20
value of ”LooP CyCL” setting under the PROGRAM parameter.
9. Frequency Hi Limit Setting
The Frequency display will indicate “FrEq” and the Voltage display shows “HI”. Press the “︿” or
“﹀” key from the Current display to adjust the high limit frequency within the range of
47.0-63.0Hz. This feature disallows user to vary the output frequency during RESET and TEST
conditions, which may cause to exceed the acceptable range of frequencies for any particular
DUTs. (Note: Else two ranges: 45.0-500.0Hz and 400Hz for option.)
10. Frequency Low Limit Setting
The Frequency display will indicate “FrEq” and the Voltage display shows “LO”. Press the “︿” or
“﹀” key from the Current display to adjust the low limit frequency within the range of 47.0-63.0
Hz. This feature disallows user to vary the output frequency during RESET and TEST conditions,
which may cause to exceed the acceptable range of frequencies for any particular DUTs. (Note:
Else two ranges: 45.0-500.0Hz and 400Hz for option.)
11. Voltage Hi Limit Setting
The Frequency display will indicate “Volt” and the Voltage display shows “HI”. Press the “︿” or
“﹀” key from the Current display to adjust the high limit voltage. This feature disallows user to
vary the output voltage during RESET and TEST conditions, which may cause to exceed the
acceptable range of voltages for any particular DUTs.
12. Voltage Low Limit Setting
The Frequency display will indicate “Volt” and the Voltage display shows “LO”. Press the “︿” or
“﹀” key from the Current display to adjust the low limit voltage. This feature disallows user to
vary the output voltage during RESET and TEST conditions, which may cause to exceed the
acceptable range of voltages for any particular DUTs.
13. Over Current Fold Back
The Frequency display will indicate “OC” and the Voltage display shows “Fold”. press the “︿” or
“﹀” key from the Current display to select ON/OFF for the output status. (The same method
applied as voltage setting). Setting On, When output current is higher than Programmable
Parameters “A-HI” current setting current value, it will keep constant A-HI setting current value
output.