EasyManua.ls Logo

EEC 6500 Series - CHAPTER 2: SPECIFICATION; 2.1 SPECIFICATION

Default Icon
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
CHAPTER 2: SPECIFICATION
2.1 SPECIFICATION
Model
6510
6520
6530
6540
6580
OUTPUT
Phase
1 Ø
Power Rating
10 kVA
20 kVA
30 kVA
40 kVA
80KVA
Voltage
Range
0 - 150 V / 0 - 300 V or 0 - 175 V / 0 - 350 V Selectable (Option 0 - 350 V) or 0 - 300 V /
0 - 600 V Selectable (Option 0 - 600 V)
Resolution
0.1 V
Accuracy
1
± (1% of setting + 2 counts)
Max. Current
(r.m.s)
2
0 - 150 V
84.0 A
168.0 A
252.0 A
336.0 A
672.0A
0 - 300 V
42.0 A
84.0 A
126.0 A
168.0 A
336.0A
Max. Current
(r.m.s)
3
for option 0 -
350 V
0 - 175 V
72.0A
144.0A
216.0A
288.0A
576.0A
0 - 350 V
36.0A
72.0A
108.0A
144.0A
288.0A
Max. Current
(r.m.s)
4
for
option 0 - 600
V
0 - 300 V
42.0 A
84.0 A
126.0 A
168.0 A
336.0A
0 - 600 V
21.0 A
42.0 A
63.0 A
84.0 A
168.0A
Frequency
5
Range
45.0 - 70.0 Hz / 45 - 500 Hz (Option) / 360 - 440, 760 - 840 Hz (Option 400 / 800 Hz)
Full Range Adjust
Resolution
0.1 Hz / 1 Hz
Accuracy
± 0.02% of setting
Total Harmonic Distortion
(THD)
6
< 1% for 110 / 220V, 50 / 60Hz for 300V and Option 350V at Resistive Load
< 1.2% for 220 / 440V, 50 / 60Hz for Option 600V at Resistive Load
Inrush Current
3 times rated Current(r.m.s)
Crest Factor
3 times rated Current(r.m.s)
Line Regulation
± 0.1 V
Load Regulation
± (0.5% of output + 0.5 V) at Resistive Load
Ramp up /
Ramp down
Range
0.1 - 999.9s
Resolution
0.1s
Accuracy
± (0.1% of setting + 0.2s)
INPUT
Phase
4W
Voltage
220 (L - N) / 380 Vac (L - L) ±10%
Max. Current
7
25 A
50 A
75 A
100 A
200A

Related product manuals