Innovating
po
we
r.
AX M2 Series 3-5 kW | Solar inverter
Solar
inverter
|
V1.7
Control and display elements - Page 36
11
Max. mains charging
current:
Note: If a smaller
value is entered in
menu point 02, the
value from 02 is used
for the mains charging
current.
2A
10A
20A
30A
(preset)
40A
50A
60A
12
Battery bank voltage
threshold:
Return from PV mode
or inverter mode in
mains mode if the
priority in menu point
01 is set to SUb or
SbU.
3KW Pre-
setting
:
23.0V
5KW Pre-
setting
:
46.0V
The setting range of the 3-kW model extends
from 22.0 V to 28.5 V, and the increment of each
click is 0.5 V.
The setting range of the 5-kW model extends
from 44.0 V to 57.0 V, and the increment of each
click is 0.2 V.