Control and display elements - Page 44
37
Charge equalization
interval of the battery
bank.
30 days (pre-set)
The setting range lies
between 0 and 90 days.
The increment of each
click is 1 day
39
Charge
equalization of the
battery bank
is immediately
started.
Deactivate (pre-set)
Activate
When the equalizing function in program 33 is
activated, this program can be configured.
When "activate" is selected in this program, the
battery equalization is activated immediately and
displayed on the LCD main page . Whenn
"deactivate" is selected, the equalizing function is
terminated until the next activated equalization
time based on the setting of program 37 occurs.
At this point in time, is
not shown in the LCD main page.
40
All stored data for
PV production
capacity and reset
output load energy
No reset (pre-set)
Reset
93
Delete all data
protocols
Delete all data protocols
Reset