21
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter Designation Unit Limits Preset for Ind.
max min 100 220 680 1000
133 LSE Thread trimming operation, when completing the 1 0 1 1 1 1 A
seam after light barrier sensing On/Off
134 SSt Softstart On/Off 1 0 1 1 1 1 A
135 SrS Ornamental backtack On/Off 1 0 0 0 0 0 A
136 FAr 0 = Trimming stitch forward and thread wiper 6 0 5 0 1 0 A
function On
1 = Trimming stitch backward and thread wiper
function On
2 = Trimming stitch forward with short trimmer
signal instead of a thread wiper
3 = No function
4 = No function
5 = Thread clamp with trimming stitch backward
6 = Thread clamp with trimming stitch forward
137 SLU Stitch length during backtack 1 0 1 1 0 0 A
0 = long stitches
1 = normal stitches
138 hPr 0 = High lift for walking foot 1 0 0 0 0 0 A
operational mode not stored
1 = High lift for walking foot
operational mode stored
139 nIS Display of machine speed On/Off 1 0 0 0 0 0 A
141 SGn Speed status for the seam with stitch counting 4 0 1 1 1 1 A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without
influence by the pedal (machine stop by
pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to
the set limit (parameter 118)
3 = At fixed speed (parameter 118) can be
interrupted by full heelback
4 = At fixed speed (parameter 110) can be
interrupted by full heelback.
142 SFn Speed status for the free seam and for the seam 3 0 0 0 0 0 A
with light barrier
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without
influence by the pedal (machine stop by
pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to
the set limit (parameter 118)
3 = At fixed speed (parameter 118) can be
interrupted by full heelback
145 StL Normal/long stitches with/without speed limitation. 2 0 0 0 0 0 A
Key on input in1...i10 = 22.
0 = Normal/long stitches without speed limitation
1 = Normal/long stitches with speed limitation
(DB2000)
2 = Normal/long stitches with speed limitation
(DB3000)
150 t8 Stitch correction of the double start ms 500 0 0 0 0 0 A
backtack (prolongation of the stitch
regulator ON period / not effective with
ornamental backtack)
151 t9 Stitch correction of the double end ms 500 0 0 0 0 0 A
backtack (prolongation of the stitch
regulator ON period / not effective with
ornamental backtack)
152 thP Run-out time of the high lift walking speed ms 500 80 100 100 100 100 A