Questions and Answers

  • M
    millercharlesAug 10, 2025
    Why does my EINHELL GC-DP 5225 N Water Pump switch off after briefly running?
    • H
      hjenkinsAug 10, 2025
      Your EINHELL Water Pump might be switching off shortly after starting due to a couple of reasons: * The motor circuit-breaker might be tripping because of excessive water contamination. If this is the case, unplug the power and clean the equipment and shaft. * Alternatively, the water temperature may be too high, causing the motor circuit-breaker to switch off the equipment. Ensure that the water temperature does not exceed 35 °C.
  • M
    Melissa MurrayAug 16, 2025
    What to do if my EINHELL GC-DP 5225 N Water Pump does not cut out?
    • Z
      zpettyAug 16, 2025
      If your EINHELL Water Pump isn't cutting out, it might be because the floating switch can't sink. Ensure the equipment is correctly placed on the shaft bottom.
  • H
    Heather ThompsonAug 23, 2025
    What to do if my EINHELL GC-DP 5225 N does not start?
    • C
      Cathy TaylorAug 23, 2025
      If your EINHELL Water Pump doesn't start, there are a couple of things you can check: * First, make sure the power supply is properly connected. * Second, check the floating switch. If it's not triggering, raise its position.
  • B
    Bradley FitzgeraldAug 28, 2025
    What to do if my EINHELL Water Pump does not pump water?
    • C
      Cheryl ChristianAug 28, 2025
      If your EINHELL Water Pump isn't pumping water, it could be due to a couple of issues: * The intake sieve might be clogged. If so, clean it with a water jet. * The discharge hose could be kinked. Straighten the hose to remove any kinks.
  • M
    Marcus MarksSep 4, 2025
    Why EINHELL GC-DP 5225 N has insufficient pumping rate?
    • D
      Dustin MahoneySep 4, 2025
      An insufficient pumping rate in your EINHELL Water Pump can occur due to: * A clogged intake sieve. Clean the intake sieve. * Reduced performance caused by heavily contaminated and abrasive water impurities. Clean the equipment and replace any worn parts.

EINHELL GC-DP 5225 N Specifications

General IconGeneral
Power520 W
Max Delivery Height25 m
Max Suction Depth/Immersion Depth7 m
Water Temperatureup to 35 °C
Power Cord10 m
Voltage230 V
Frequency50 Hz
Min Suction Level20 cm
Hose Connection1 inch
Inlet/Outlet Diameter1 inch