EasyManuals Logo
Home>EINHELL>Water Pump>GC-DP 9035 N

EINHELL GC-DP 9035 N User Manual

EINHELL GC-DP 9035 N
Go to English
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
GB
- 20 -
11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected
- Floating switch does trigger
- Check power supply
- Raise position of oating switch
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Floating switch cannot sink - Place equipment correctly on shaft
bottom
Insu cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o after brie y
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
Anl_GC_DP_9035_N_SPK9.indb 20Anl_GC_DP_9035_N_SPK9.indb 20 15.06.2018 09:29:5815.06.2018 09:29:58