9. Troubleshooting
Fault Cause Remedy
Engine does not
start
- Spark plug fouled
- Air lter dirty
- No fuel in the tank
- Automatic oil cut-out has not
responded
- Clean or replace the spark plug
- Clean the air lter.
- Top up fuel.
- Check oil level, top up engine oil
Pump fails to prime - Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake cage (intake valve) blocked
- Max. intake head exceeded
- Place the intake valve in the water
- Fill the pump chamber with water
through the ller neck
- Check the intake line for leaks and
seal it if necessary.
- Clean intake cage
- Check intake head and reduce it if
necessary
Insu cient pumping
rate
- Intake head too high
- Intake cage soiled
- Water level falling rapidly and intake
line is out of the water-
- Pump performance reduced by de-
posits
- Check intake head and reduce it if
necessary
- Clean intake cage
- Place the intake line at a deeper
level
- Clean pump
Important. The pump must not run dry.
Anl_GE_PW_46_SPK7.indb 20Anl_GE_PW_46_SPK7.indb 20 25.03.2019 10:10:3825.03.2019 10:10:38