6. POSSIBLE ALARMS
Type of
alarm
Alarm description
Cause of the alarm
Effect
E1
(In red)
Cooking chamber
temperature probe
not detected
Connection interrupted
between cooking chamber
probe and
micro power board
Impossible to start
cooking
E2
(In
orange)
Core probe not
detected
Improper "plug - socket"
connection of the probe to
the core probe
It is not possible to
activate a cooking
cycle with
the “core
temperature”
parameter
Needle-shaped
core probe
interrupted/damaged
E3
(In red)
Safety thermostat
on
Maximum allowable
temperature in the cooking
chamber exceeded
Oven operation
deactivated
E4
(In red)
Thermal motor
safety protection
activated
Motor overheated
Oven operation
deactivated
E8
(In red)
Display board
overtemperature
Overtemperature above
70°C on the display board
Oven operation
deactivated
E9
(In red)
Main micro power
board
overtemperature
Overtemperature on the
micro power board above
70°C
Oven operation
deactivated
E10
(In
orange)
Automatic washing
cycle cannot
be activated
The temperature in the
cooking chamber exceeds
90°C
The automatic
washing cycle does
not work
Cool the cooking
chamber: open the door
and touch the
symbol (automatic
cooling is activated).
E11
(In red)
Condensation hood
not working
The hood’s power cable is
not connected to the
mains
Oven operation
disabled. If a
cooking cycle is in
progress, it is
completed.
E12
(In red)
Hood condensation
chamber
temperature probe,
not working
Connection interrupted
between condensation
chamber temperature
probe and
electronic board
Oven operation
disabled. If a
cooking cycle is in
progress, it is
completed.
E13
(In
purple)
Proofer
temperature probe
not detected
Connection interrupted
between proofing
chamber probe and
micro power board
Cannot start the
proofing cycle
E14
(In
purple)
Holding cabinet
temperature probe
not detected
Connection interrupted
between holding
chamber probe and micro
power board
Cannot start the
holding cycle