EKO BOILER
MANU
AL
24
Problem
Cause
Remedy Suggested
Regulator does not work
No power
Check the wiring and circuit
breakers
Fuse damaged
Replace fuse not covered
by warranty
Live wire conduit damaged
Inspect and repair wire
Temperature sensor
damaged
Call service
Regulator damaged
Call service
Blower fan not working
Thermal protection engages
Investigate reasons for boiler
overheating
No power in regulator
Check fuse and wiring
Fan damaged
Call service fan
replacement
Regulator damaged
Call service
Fan blocked
Inspect and clean the fan
Blower fan making noise
Bearings damaged
Call service fan
replacement
Condenser damaged
Call service fan
replacement
Fan clips loosened
Check, turn the clips tight
Fan blades dirty
Clean and check
Debris in fan cover
Clean and check
Blower fan working poorly
Dirty fan blades
Check and clean
Creosote on the fan cover
Check and clean
Explosion or puffing in the
firebox
Problems with startup
Refer to page 17
Chimney draft too low (below
0.40”wc)
Rebuild chimney. Consider
use of WKO exhaust fan
Chimney draft too intensive
(over .080”wc)
Use exhaust regulator
Wood too small or too dry
Mix with larger humidity fuel
as to increase humidity level
(should be about 15-35%)
Clogged heat exchanger
tubes
Clean the exchanger or call
service not covered by
warranty