Boiler Technical Data
Boiler Type
um
ORLAN
18
ORLAN
25
ORLAN
40
ORLAN
60
ORLAN
80
Power
kW
4+18
5+31
8+40
15+60
25+80
Efficiency
%
85
91
91
91
91
Weight STANDARD *
lb
870
1124
1279
2006
2458
Weight SUPER *
lb
937
1157
1312
2150
2568
Casing height approx
A-inch
44
52.7
61.8
60.4
62
Heating water outlet height -
approx
B-inch
47.6
51.4
61.4
62
64
Heating water inlet height -
approx
C-inch
8.5
9.3
8.7
8.3
9.6
Waste outlet height - approx
D-inch
5.7
5.7
5.1
5.7
6.9
Chimney conduit height -
approx
E-inch
34.3
37.8
48
46
47.6
Casing width - approx
G-inch
21.5
23.6
23.6
29.1
29.1
Depth - approx
H-inch
37.8
40.9
40.2
52.8
67
Heating water outlet - approx
I-inch
13.4
12.6
13
22.6
23.6
Chimney conduit diameter -
approx
J-inch
7.1
7.9
7.9
8.3
8.3
Width with a coil - approx
K-inch
26
28.3
28.3
33.9
33.9
Height of coil connection -
approx
L-inch
39
43.3
52.4
51.6
51.2
Coil outlet - approx
M-inch
10.2
5.9
10.2
14.4
12.4
Diameter of feeding and return
ferrule
Q-inch
2
2
2
2-1/2
2-1/2
Diameter of the coil ferrule
R-inch
¾
¾
¾
¾
¾
Diameter of a drain valve
S-inch
½
½
½
½
1/2
Water capacity
gallons
14.5
19.75
24.5
47.5
54
Loading chamber capacity
(gasification)
ft3
4.1
6.5
11
16.4
Power consumption
W
50
50
50
100
100
Wood length
inch
20
20
20
30
39
Wood
humidity
recommended
%
15-25
admissible
%
15-25
Voltage / frequency
V/Hz
230/50

Table of Contents