EasyManua.ls Logo

Electrolux W3 SERIES - Page 40

Electrolux W3 SERIES
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
Installation manual
Mount the nipple to the steam valve. Mount the steam valve on the machine. Mount nipple, strainer and elbow. Note
the direction of the strainer. Mount steam hose to the elbow. Check that there are no sharp angles or bends on the
connected steam hose.
fig.5862C
Mount the hose with wires between steam valve and machine. Connect the wires to the steam valve. Connect ground
cable to the terminal ground connection. Connect the ”HEAT” cable connector to the ”HEAT” terminal on the I/O
board.
”HEAT”
fig.6604B
Steam pressure required:
minimum: 50 kPa (0.5 kp/cm
2
)
maximum: 800 kPa (8 kp/cm
2
)
recommended: 600 kPa (6 kp/cm
2
)
Note!
A steam heated machine is only intended to use clean steam.