Capacitive Fuel Level: The resistive and capacitive inputs share channels. Only one input type should be used
per channel.
Input Trigger Level: 2.1 Volts
Frequency Range: 0 to 15KHz.
Input Impedance: 33.2K Ohms
Sensitivity: 14 counts per Hz..
Notes: The Capacitive Fuel Level inputs may be used to monitor other functions.
EDC-33T (Both RPM Channels):
Input Trigger: +.39V / 0V (Hysteresis)
Input Resistance: 20K ohms
Max RPM: 123 Hz.
Accuracy: <= .5%
EDC-33T-H1:
Ch 1, Rotor:
Input Trigger: +.39V / 0V (Hysteresis)
Input Resistance: 20K ohms
Max RPM: 266 Hz.
Sensitivity: 372 sensor counts per Hz.
Accuracy: <= .5%
Ch 2, N1:
Input Trigger: +.11V / 0V (Hysteresis)
Input Resistance: 20K ohms
Max RPM: 6140 Hz.
Sensitivity: 16.1 sensor counts per Hz.
Accuracy: <= .5%
EDC-33T-W (Both RPM Channels):
Input Trigger: +.054V / 0V (Hysteresis)
Input Resistance: >1M ohm
Max RPM: 11.0 KHz.
Sensitivity: 8.963 sensor counts per Hz.
Accuracy: <= .5%
Pressure:
Input: 0 to 2.5 Volts Differential
Input Impedance: > 20M Ohms
Common Mode Range on the Input: + 4 Volts to -.2 Volts (from ground).
+5 Volt and Ground provided to energize the pressure transducer.
Sensitivity: Ratiometric to the EDC +5 Volt supply (9.537uV x (5/(voltage of the EDC +5V supply)))
Notes: Many pressure transducers are available to monitor many different functions. See an E.I. price sheet for a