4 Advanced System Operation
iConnect
Installation Manual
25
4.7.4. Siren Test
To test the Control System’s built-in siren:
From the Service menu, select Siren Test [7032]; the Control System’s built-in siren is sounded briefly.
4.7.5. Interface Test
The Interface test enables you to check if the speaker, LEDs and LCD are functioning correctly.
To test the system interface:
From the Service menu, select Interface Test [7033]; a short sequence of chimes are sounded from the speaker, all LEDs
flash and the LCD is tested on all connected LCD keypads.
4.7.6. Walk Test
To initiate Walk Test mode:
1. From the Service menu, select Walk Test [7034]; a list of registered detectors appears.
2. Trigger each detector; when the system receives a successful transmission from a detector, the detector is
removed from the list.
3. When all the detectors are removed from the list, End Walk Test is displayed.
4. Press Χ to exit Walk Test mode.
4.7.7. Snapshot Test
The Snapshot Test enables you to check if the video verification detector cameras are functioning correctly
To test the video verification detector cameras:
1. From the Service menu, select Test and then Snapshot Test [7035]; a list of registered detectors appears.
2. Select a detector from the list and press √; a snapshot of the monitored area in taken and the results can be viewed
in the Web User Application.
3. Repeat the test for each installed detector.
4. Press Χ to exit Snapshot Test mode.
4.7.8. Transmitters
The Transmitters menu offers a number of utilities that serve as a valuable aid during installation.
TX List
The TX List is a scrollable inventory of all registered transmitters and their last reported status.
To view the TX list:
1. From the Service menu, select Transmitters, TX List [7041]; the first transmitter on the list is displayed.
2. Using the arrow buttons, scroll through the transmitter list.
3. When you have finished viewing, press Χ to exit the list.
The TX list displays the following information for each transmitter:
The zone/device number or descriptor. Press the
key to toggle the display.
The signal strength of the last received transmission.
An abbreviation indicating the last received status of the transmitter – see Table 4-1.
Table 4-1: Transmitter Status Abbreviations
Item Description
OK The transmitter is functioning correctly
TA Tamper condition
BT Battery low
OS The transmitter is out of synchronization
NA The transmitter is inactive – see p. 36, 7.2.3 Supervision Time