PS 9000 T Series
3.6 Alarms and monitoring
3.6.1 Device alarm handling
A device alarm incident will usually lead to DC output switch-off. Some alarms must be acknowledged (see below),
which can only happen if the cause of the alarm is not persistent anymore. Other alarms acknowledge themselves
if the cause has vanished, like the OT and the PF alarm.
How to acknowledge an alarm in the display (during manual control)
1. If the alarm is indicated as a pop-up, tap OK.
2. If the alarm has already been acknowledged, but is still displayed in the status area,
thenrsttapthestatusareatodisplaythepop-up,andthenacknowledgewithOK.
In order to acknowledge an alarm during analog remote control, see „3.5.4.3. Acknowledging device alarms“. To
acknowledge in digital remote, refer to the external documentation “Programming ModBus & SCPI”.
Somedevicealarmsarecongurable:
Alarm Meaning Description Range Indication
OVP
OverVoltage
Protection
Triggers an alarm if the DC output voltage reaches the
denedthreshold.TheDCoutputwillbeswitchedoff.
0 V...1.1*U
Nom
Display, analog
IF, digital IF
OCP
OverCurrent
Protection
Triggers an alarm if the DC output current reaches the
denedthreshold.TheDCoutputwillbeswitchedoff.
0 A...1.1*I
Nom
Display, digital
IF
OPP
OverPower
Protection
Triggers an alarm if the DC output power reaches the
denedthreshold.TheDCoutputwillbeswitchedoff.
0 W...1.1*P
Nom
Display, digital
IF
Thesedevicealarmscan’tbeconguredandarebasedonhardware:
Alarm Meaning Description Indication
PF Power Fail
AC supply over- or undervoltage. Triggers an alarm if the AC supply is
outofspecicationorwhenthedeviceiscutfromsupply,forexample
when switching it off with the power switch. The DC output will be
switched off.
Display, analog &
digital interface
OT
OverTem-
perature
Triggers an alarm if the internal temperature reaches a certain limit.
The DC output will be switched off.
Display, analog &
digital interface
How to congure the device alarms
1. While the DC output is switched off, tap the touch area on the main screen.
2. In the menu tap on “Settings” and then on “Protection Settings”.
3. Set the thresholds for the device alarms relevant to your application if the default value of 103% (OVP) resp.
110% (OCP, OPP) is unsuitable.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
“Direct input”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elektro-Automatik PS 9000 T Series and is the answer not in the manual?

Elektro-Automatik PS 9000 T Series Specifications

General IconGeneral
BrandElektro-Automatik
ModelPS 9000 T Series
CategoryPower Supply
LanguageEnglish

Related product manuals