EasyManuals Logo

Elektro-Automatik PS 9000 T Series User Manual

Elektro-Automatik PS 9000 T Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
Page 58
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
PS 9000 T Series
4. Service and maintenance
4.1 Maintenance / cleaning
The device needs no maintenance. Cleaning may be needed for the internal fan, the frequency of cleanse is
depending on the ambient conditions. The fan serves to cool the components which are heated by the inherent
powerloss.AheavilydirtlledfancanleadtoinsufcientairowandthereforetheDCoutputwouldswitchofftoo
early due to overheating or possibly lead to defects.
Cleaning the internal fans can be performed with a vacuum cleaner or similar. For this the device probably requires
to be opened.
4.2 Fault nding / diagnosis / repair
If the equipment suddenly performs in an unexpected way, which indicates a fault, or it has an obvious defect, this
can not and must not be repaired by the user. Contact the supplier in case of suspicion and elicit the steps to be
taken.
It will then usually be necessary to return the device to the supplier (with or without guarantee). If a return for
checking or repair is to be carried out, ensure that:
• thesupplierhasbeencontactedanditisclariedhowandwheretheequipmentshouldbesent.
• the device is in fully assembled state and in suitable transport packaging, ideally the original packaging.
• optional extras such as an AnyBus interface module is included if this is in any way connected to the problem.
• a fault description in as much detail as possible is attached.
• if shipping destination is abroad, the necessary customs papers are attached.
4.2.1 Replacing a defect mains fuse
Thedeviceisprotectedone5x20mmfuse(forvaluecheckfusebodyortechnicalspecicationsin1.8.3) which
is located on the rear of the device, inside a fuse holder (separate or in the AC socket, depends on the model).
To replace the fuse, the device is not required to be opened. Just remove the power cord and unscrew the fuse
holderwithaatscrewdriver.Thereplacementfusemustbeofsamevalueandtype.
4.2.2 Firmware updates
Firmwareupdatesshouldonlybeinstallediftheycaneliminatesoftwarebugsinthermware
of your device or contain new features.
Thermwareofthecontrolpanel(HMI),ofthecommunicationunit(KE)andthedigitalcontroller(DR),ifneces-
sary, is updated via the rear side USB port. For this the software “EA Power Control” is needed which is included
withthedeviceoravailableasdownloadfromourwebsite,togetherwiththermwareupdate,oruponrequest.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elektro-Automatik PS 9000 T Series and is the answer not in the manual?

Elektro-Automatik PS 9000 T Series Specifications

General IconGeneral
BrandElektro-Automatik
ModelPS 9000 T Series
CategoryPower Supply
LanguageEnglish

Related product manuals