OPERATING the FIREPLACE
Element4 Gas Fireplaces EuropeanHome.com
Automatic Turndown.
1. In Manual/Temperature/Timer modes, the valve will turn to pilot ame if there is no change in ame height for a six hour
period. In Temperature or Timer mode, if the ambient room temperature changes, the ame height will adjust automatically to
maintain set temperature and the re will continue to function normally. The valve will turn to pilot ame if the set temperature
and the ambient room temperature remain the same over a six hour period.
2. The valve turns to pilot ame if the temperature in the receiver is higher than 140°F/60°C. The burners comes back on only
when the temperature is below 140°F/60°C.
Automatic Shut O.
1. With low battery power in the receiver, the system shuts o the re completely. This does not happen if the power supply is
interrupted.
2. The system shuts o the re completely if there is no change in ame height for 5 days.
3. The system shuts o the re if the main burner does not completely ignite approximately 20 seconds after ignition or after
pushing the Ç button.
Timer mode.
The appliance must be in standby mode, pilot ignited. The Timer setting allows you to set 2 burner Temp times and 2 burner
Temp times every 24 hrs.
For Temp to operate as a thermostat, TEMP must be set at 4°C or higher.
If the Temp setting is decreased to - -, the motor will turn the valve to the standby position in the moon times and await the
next burner Temp cycle.
Setting the Temperature.
Select either the Temp MODE or the Temp MODE by briey pressing the SET button.
Hold the SET button until the TEMP display ashes.
Set the desired temperature withÈorÇ.
Press OFF to complete the program.
Setting the Timer.
Select Timer mode by briey pressing the SET button.
Press and hold the SET button until the P1 is displayed, and the time ashes. Set the hour by pressingÇand set the minutes by
pressingÈ.
Briey press SET button for the next burner cycle time.
Once all 4 times are set, press OFF to complete the programming.