EasyManuals Logo

ELGO Electric P8511 Series User Manual

ELGO Electric P8511 Series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
running into the ends of the machine. The end limit values are modified by backlash value
as set in R4, if R8/6 is selected.
R15 Software Limit / End Limits Selection
Software limits (R13 & R14) are active in accordance with the setting of R15/6
xxxxx0 Both software limits active
xxxxx1 Min software limit (R13) inhibited
xxxxx2 Max software limit (R14) inhibited
xxxxx3 Both software limits (R13&R14) inhibited
External limit switches can be connected to the St3/3 negative direction and at St3/7 for
positive direction.
xxxx0x Both limits inputs active
xxxx1x Min limit input (St3/3) inhibited
xxxx2x Max limit input (St3/7) inhibited
xxxx3x Both software limit inputs (St3/3 St3/7) inhibited
N.B If these are not connected to limit switches they need to be connected Normally
closed (i.e. linked out).
R17 Display Brightness
Setting this parameter changes the brightness of the display.
0 = dark, and 15 = maximum brightness.