motor voltage | 120 V |
---|---|
motor frequency | 60 Hz |
motor current | 3 amp |
maximum gate size | 14' wide |
---|---|
maximum gate weight | 500 lbs |
travel speed | 18 to 21 seconds 90° opening |
torque | 450 lbs |
---|---|
worm gear reduction ratio | 27:1 |
output shaft diameter | 1 1/4" |
length when open | 44 1/2" |
---|---|
length when closed | 29 1/4" |
height | 7 1/2" |
width | 4 1/2" |
Key safety rules for gate placement, size limits, and compatibility with water and traffic.
Critical instructions for product operation, wiring, lubrication, and safe handling.
Guidelines for reinforcing gate posts with re-bar, steel plates, and angles.
Requirements for gate spacing and specific measurement plans for outside opening.
Guidelines for reinforcing gate posts with re-bar, steel plates, and angles.
Requirements for gate spacing and specific measurement plans for inside opening.
Step 1: Position and level operator, tack weld plate and brackets.
Step 2: Fully weld plates and brackets, remove operator.
Step 3: Ensure operator is level for proper function.
Step 4: Install positive stops for opening and closing.
Step 5: Determine location, mark, and drill holes for mounting.
Step 6: Align operator on post and tap in pin.
Steps 7 & 9: Snap retaining clip to secure the pin.
Step 8: Position arm, align holes, and tap in pin.
Step 10: Gently tap in plastic key release cover (optional).
Diagrams illustrating correct and incorrect bracket welding.
Wiring diagram and instructions for connecting power to a single operator.
Specifies wire gauge and emphasizes proper grounding.
Wiring diagram for connecting power to master and slave operators.
Details on conduit use, wire gauge, and grounding.
Instructions for connecting wires to choose open inside or outside.
How to adjust the sensor for proper gate stopping.
Jumper ON: Unit releases actuator upon reaching limit.
Jumper OFF: Unit stops actuator upon reaching limit.
Explanation of LEDs for relay status, power, motor error, and sensors.
Numbered list identifying board components like fuses, pots, switches, and plugs.
Instructions for mounting the receiver inside the control board box.
Diagram showing connections for key switch, reader, button, and detector.
Diagrams showing loop placement (A & B) and wire gauge.
Wiring instructions for loop wires to the J2 terminal.
Wiring the proximity switch (NO & COM) to the J2 terminal.
How the actuator can be interfaced with an existing house alarm panel.
Wiring for a 12VDC alarm/strobe light.
Diagrams showing connections for multiple proximity switches.
Recommended placement and switch setting for the photocell.
Wiring diagram for connecting a photocell to the master operator.
Important switch setting for the photocell on the slave operator.
Wiring diagram for connecting a photocell to the slave operator.
Wiring diagram for a 12VDC magnetic lock with a relay.
Wiring diagram for a 24VDC magnetic lock with a relay.
Notes on required components for magnetic lock interface.
Steps for inserting and turning the key to release the gate.
Steps for re-locking the operator after manual gate movement.
Explanation of how troubleshooting LEDs indicate system status.
Examples of issues related to radio receiver 'ON' or 'OFF' states.
Steps to detach plugs, remove nuts, and take out the control board.
Diagram labeling all parts with their corresponding codes.
Details on motor type, power, worm gear reduction, and cycles.
Maximum gate size, weight, and opening speed.
Physical dimensions, torque rating, and body finishing.
Description of the modular board's LEDs and the emergency release.